LC-DAD-FLD法测定金属包装彩印面3种光引发剂的迁移量
DOI:
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

基金项目:


Determination of Migration of 3 Photoinitiators from Printing Surface of Metal Packaging by LC-DAD-FLD
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    为了评估金属包装彩印面的光引发剂迁移风险,建立了一种基于液相色谱(LC-DAD-FLD)分析金属包装彩印面中BP、4-MBP和2-ITX 3种光引发剂迁移量的检测方法。并对DAD的检测波长、FLD检测的激发波长和发射波长等参数进行了优化,对食品模拟液和迁移条件进行了选择。实验结果表明,对液相色谱条件进行优化后,3种光引发剂BP、4-MBP和2-ITX的检出限分别为0.05,0.05,0.003 mg/L,加标回收率为90.88%~106.83%,精密度小于7.90%。可见,所提方法满足EuPIA对于BP、4-MBP和2-ITX的特定迁移限量要求。

    Abstract:

    In order to investigate the migration risk of the PIs from the printing surface of metal packaging, the migrations of BP, 4-MBP and 2-ITX from the printing surface of metal packaging were determined by liquid chromatography (LC-DAD-FLD). The DAD detection wavelength, FLD excitation wavelength and FLD emission wavelength were optimized, and the food simulants and migration conditions were selected. The results showed that after optimizing the conditions of the liquid chromatography, the detection limits of BP, 4-MBP and 2-ITX were 0.05, 0.05 and 0.003 mg/L respectively. The recoveries ranged from 90.88% to 106.83%, and the RSD was below 7.90%. Therefore the method was suitable for the SML requirements for BP, 4-MBP and 2-ITX of EuPIA.

    参考文献
    相似文献
    引证文献
引用本文

李灿明,柏建国,陈江龙,白燕楠. LC-DAD-FLD法测定金属包装彩印面3种光引发剂的迁移量[J].包装学报,2017,9(2):68-73.