Abstract:Based on the concave hexagonal negative Poisson’s ratio (NPR) bottom anti-collision protection structure, the heat dissipation, an analysis and optimization have been made of the heat dissipation, temperature equalization, and flow resistance performance of the chassis integrated battery pack (CTC) liquid cooling system. Firstly, under the conditions of 2C discharge rate, a comparison, as well as an analysis, is made of coolant inlet flow rate of 0.3 m/s, and ambient temperature of 25℃, and the system heat dissipation performance and pressure drop of three liquid cooling channel schemes, scheme 3 with the smallest temperature difference and pressure drop to be selected for optimization. A disturbance element structure is proposed in the flow channels, based on the second-generation non-dominated sorting genetic algorithm (NSGA-II), with the maximum temperature Tmax, maximum temperature difference ΔTmax, and flow channel pressure drop ΔP of the liquid cooling system taken as the objective functions, and the disturbance element width W, spacing D, and coolant flow rate v used as variables for multi-objective optimization. The results indicate that the optimal performance of the liquid cooling system can be achieved when W=2.356 mm, D=48.468 mm, and v=0.216 m/s. After optimization, the maximum temperature, maximum temperature difference, and flow channel pressure drop of the liquid cooling system are 300.46 K, 2.22 K, and 6 376.77 Pa, respectively. The flow channel pressure drop is reduced by about 38.3% compared to the initial scheme, which ensures heat dissipation performance as well as reduces system energy consumption, thus providing theoretical reference for the thermal safety design of CTC-type battery packs.